Technical Information
● Max Scan angle:
|
±30°optical (factory calibration @±20°)
|
● Mirror Size:
|
6mm*11mm*0.7mm, (5mm*10mm*0.7mm for higher speed)
|
● Mirror coating:
|
High quality dielectric film,
|
● Reflectivity:
|
>98% @45°incidence(400nm-700nm)
|
● Dimension of Galvo:
|
12.7mm (diameter for fixture ) x mm (length without mirror)
|
● Power requirements:
|
±24VDC @1.2A each
|
● Input Voltage:
|
±5VDC differential
|
● Dimensions of Amp:
|
81.6mm*62.5mm*33mm
|
● Protection Circuitry:
|
Input clamping and power limiter circuit built in Amp.
|
Scan Speed
Scan angle
|
Operating voltage
|
Speed @ Mirror size
|
Speed @ Mirror size
|
Test Pattern |
±30°Opt
|
±24 VDC
|
31Kpps @ 6*11*0.7
|
33Kpps @5*10*0.7
|
ILDA 30K |
±20°Opt
|
±24 VDC
|
40Kpps @ 6*11*0.7
|
43Kpps @5*10*0.7
|
ILDA 30K |
±15°Opt
|
±24 VDC
|
51Kpps @ 6*11*0.7
|
53Kpps @5*10*0.7
|
ILDA 30K |
±12°Opt
|
±24 VDC
|
60Kpps @ 6*11*0.7
|
64Kpps@ 5*10*0.7
|
ILDA 30K |
*±5°Opt
|
±24 VDC
|
80Kpps @ 6*11*0.7
|
82Kpps @5*10*0.7
|
ILDA 30K |
The blue mark is standard product. If order on batch there will be a discount.
Contents of Shipping Package
(1) 2 x 2802 Scanner (Galvo) with mirror
(2) 2 x Scan V4.3A servo driver (Amp)
(3) 1 x (X-Y) scanner mount
(4) 1 x ±24 VDC switched power supply
(5) 2 x Shield cable for scanner
|